Colombo · Since 2003 · CEB-retired engineering team
Substations built. Transformers kept alive.
Power Logic Engineers designs, supplies, installs, tests and maintains HV, MV and LV electrical systems across Sri Lanka — from 132kV substations down to the panel on your factory floor.
The company
An independent electrical contractor and distributor — not a reseller with a van. The founding team came out of the Ceylon Electricity Board, and the work is still specified, tested and signed off by engineers.
Power Logic Engineers (Pvt) Ltd began operations in 2003, founded by a group of CEB-retired engineers. The target from day one: proper engineering support for medium-voltage bulk customers — repairs, maintenance and low-voltage industrial projects at competitive prices, with qualified technical backup and a reliable scope for material supply and installation anywhere in Sri Lanka.
With combined experience of 20+ years across power generation, transmission and distribution, the teams serve factories, utilities, commercial buildings and infrastructure operators. The difference clients notice is practical: flexible, reliable service support, and a crew that answers in an emergency and takes responsibility for the work.
PLE is an authorised service partner for Lauritz Knudsen Electrical & Automation (ex-L&T, India) and BBC Cellpack GmbH (Germany), and supplies equipment from Cooper Power Systems, Tyco Electronics / Raychem, Hering AG and TJH2B.
- Founded2003, Colombo — by CEB-retired engineers
- ScopeFull EPC: design → supply → install → test → maintain
- CoverageProjects and service calls across Sri Lanka
- Sales / ServiceMr. Sanjaya Wellala — 077 408 4425
Business scope
What the company actually does, in its own terms — engineering services for medium-voltage bulk customers, backed by its own supply lines.
- 20+ years of combined experience in power generation, transmission and distribution, led by CEB-retired engineers.
- Repairs, maintenance and low-voltage industrial projects for medium-voltage bulk customers, with qualified technical backup.
- Flexible, reliable customer service — including emergency attendance and annual maintenance arrangements, anywhere in Sri Lanka.
- Authorised supply from BBC Cellpack GmbH, Cooper Power Systems, Tyco Electronics, Hering AG, TJH2B, L&T Switchgears and more.
How a project runs
Four core services cover every engagement, from a single repair to a complete substation contract.
Project Planning & Designing
Planning and designing of any kind of electrical project, handled by a highly qualified in-house design team.
Material Supply & Installation
Complete EPC contracts — import, supply and installation covering the full project scope.
Testing & Commissioning
All electrical testing conducted in-house by specialised technical teams before handover.
Maintenance & Services
Regular and annual maintenance and repair services for all kinds of electrical installations.
Core management
Cyril Wellala has more than 45 years of experience in power generation, transmission and distribution, including 35+ years with the Ceylon Electricity Board covering Hydro, Thermal and Coal generation, transmission up to 220kV and substations up to 132kV.
- Honoured as a long-serviced CEB employee in 2007.
- Expert in cable laying, termination and jointing up to 132kV.
- Expert in transformer fault rectifying and repairing.
Authorised partners
PLE is the authorised partner behind the equipment it supplies — covering MV switchgear (AIS, GIS), MV cable termination and jointing, transformer oil testing and SF6 gas laboratory testing.
Lauritz Knudsen Electrical & Automation
Formerly L&T Electrical & Automation. MV and LV switchgear, including AIS and GIS ranges at 11/33kV.
BBC Cellpack GmbH
German manufacturer of heat-shrink termination and jointing systems for LV and MV cables.
Raychem — TE Connectivity
Raychem (Tyco Electronics / TE Connectivity) cable accessories, supplied through PLE.
TJH2B
Cable accessories supplied alongside the Cellpack and Raychem ranges.
Featured services
Three of the twelve. Every service has its own page with scope, specifications and a quotation route.
SERVICE 02 / 12Electrical substation installation
11kV · 33kV — INDOOR / OUTDOORDesign, installation, testing and commissioning of 11/33kV indoor and outdoor substations.
View page →
SERVICE 03 / 12Transformer installation & testing
132 / 33 / 11 / 0.4kVInstallation, testing and commissioning of power and distribution transformers up to 132kV.
View page →
SERVICE 06 / 12Transformer Condition Assessment
TCA · DGA · OIL TESTINGA full health verdict on a transformer: DGA, moisture and oil tests, windings and bushings — repair or run.
View page →Featured products
Three of the ten product lines PLE imports and supplies — the same equipment its crews install.
PRODUCT 01 / 1033/11/0.4 kV Power / Distribution Transformers and rectifiers
33 · 11 · 0.4kVPower and distribution transformers at 33/11/0.4kV, plus rectifiers — supplied, installed and maintained by one company.
View page →
PRODUCT 02 / 1011/33kV VCB, AIS and GIS Switchgear
11kV · 33kV — LAURITZ KNUDSEN (EX-L&T)Vacuum circuit breaker, air-insulated and gas-insulated switchgear at 11/33kV — Lauritz Knudsen / ex-L&T range.
View page →
PRODUCT 09 / 10Low voltage and medium voltage cable accessories — BBC Cellpack
LV · MV — TERMINATION & JOINTING KITS, TAPESTermination kits, jointing kits and insulation tapes — BBC Cellpack heat-shrink cable accessories.
View page →Testing & diagnostics
Most transformer and switchgear failures announce themselves months early — in the oil, in a hot joint, in a partial discharge. PLE's in-house test teams find them before they trip your plant. Each test below is covered in depth on its own service page.
| Dissolved Gas Analysis (DGA) | Gases dissolved in transformer oil reveal overheating, arcing and insulation breakdown inside the tank — long before failure. See Transformer Condition Assessment. |
|---|---|
| Transformer Condition Assessment | A full health verdict on the unit: oil, windings, bushings and accessories, with a repair-or-run recommendation. |
| Oil testing & purification | Moisture content, dielectric strength and full oil test suite — then filtration on site to restore the oil. See Transformer oil purification. |
| Partial discharge (PD) | Locates insulation defects in transformers, switchgear, power cables and MV machinery. See Partial Discharge Analysis. |
| Thermography | Infrared scan of panels and connections under load. See Thermography testing. |
| Relay testing & calibration | Protection relays on 11/33kV OCB/VCB switchgear proven to trip at the set values. See Protection relay testing. |
| SF₆ gas testing & filling | 33kV GIS maintenance: gas quality checked, topped up and leak-tested. See Switchgear Maintenance. |
| Earth, RCD & safety audit | Earth resistance, RCD trip testing and a written electrical safety audit report for your installation. |
| Cable fault location | Pinpoints underground cable faults so you dig once, in the right place. See Cable laying and drumming. |
In their words
Testimonials published by Power Logic Engineers from its industrial clients.
“Power Logic Engineers do a great job on any entrusted work in the electrical field, especially HT or LT work. A professional team that handles any situation effectively and efficiently — there to support us in emergency situations, taking responsibility for what they do, with immediate attendance at any time, under any condition.”
“33kV transformer maintenance and SF₆ GIS maintenance conducted annually with great satisfaction. A professional, well-experienced team with great practical problem-solving.”
“Engineering imports, supply, installation, testing and commissioning service provider” — cited by the operations team at Eco Power for PLE's end-to-end delivery.
Asked often
Straight answers, drawn from the services PLE lists and performs.
What is the highest voltage you work at?
Can you take a whole substation project, or only parts of it?
My transformer is old. How do I know if it needs repair or replacement?
Do you respond to breakdowns outside office hours?
Are you tied to one brand of switchgear or cable accessories?
Talk to an engineer
658/89A Mahawela Gardens, Baseline Road, Colombo 00900 · powerlogiceng@sltnet.lk
Office: +94 11 267 9502 · +94 11 269 2949